SECTION 02815 Glass Fiber Reinforced Concrete Benches
PART 1 GENERAL
1.1 SECTION INCLUDES
- Glass fiber reinforced concrete (GFRC) benches as indicated on the drawings.
 
1.2 RELATED SECTIONS
- Division 04 Section "Cast Stone".
 - Division 05 Section "Metal Fabrications" for supplementary supports for large items.
 - Division 06 Section "Rough Carpentry" for supplementary supports for large items.
 - Division 06 Section "Glass Fiber Reinforced Plastic Fabrications".
 - Division 09 Section "Glass Fiber Reinforced Gypsum Fabrications".
 - Division 09 Section "Paints and Coatings" for field painting and sealing prior to painting.
 
1.3 REFERENCES
- ASTM C 150 - Standard Specification for Portland Cement; 1999a.
 - ASTM C 33-99 Concrete Aggregates
 - ASTM C 666 - Standard test Method for Resistance of Concrete to Rapid Freezing and Thawing
 - ASTM C 979-82(1993): Pigments for Integrally colored Concrete.
 - ASTM E 84 - Standard Test Method for Surface Burning Characteristics of Building Materials; 1999.
 - ASTM G 23 - Standard Practice for Operating Light-Exposure Apparatus (Carbon-Arc Type) With and Without Water for Exposure of Nonmetallic Materials; 1996.
 
1.4 SUBMITTALS
- Submit under provisions of Section 01300.
 - Product Data: Manufacturer's data sheets on each product to be used, including dimensions, finishes, storage and handling requirements and recommendations, and installation recommendations.
 - Shop Drawings: For custom items, provide drawings showing dimensions, layout, joints, details, and interface with adjacent work; include field measured dimensions of the spaces where items are to be installed, if critical to proper installation.
 - Samples: For each custom finish specified, two samples, minimum size 6 inches (150 mm) square, representing actual product, color, and patterns.
 
1.5 QUALITY ASSURANCE
- Manufacturer: Obtain GFRC benches as manufactured by a firm specializing in the manufacture of GFRC benches, with a minimum of ten years experience.
 - Provide a list of projects comparable in size, scope, and complexity as indicated.
 - Provide verification that glass fiber reinforced concrete bench meets or exceeds products specified.
 - Installer Qualifications: Regularly engaged and experienced in the installation of glass fiber reinforced concrete products.
 
1.6 DELIVERY, STORAGE, AND HANDLING
- Transport, lift, and handle units with care, avoiding excessive stress and preventing damage; use appropriate equipment.
 - Store products in manufacturer's unopened packaging until ready for installation, in a clean dry area protected from weather, moisture and damage; store units upright and not stacked unless permitted by manufacturer. Product shall be stored clear of the ground on non-staining pallets or other temporary planking.
 - Protect product from staining, chipping, and other damage.
 
PART 2 PRODUCTS
2.1 MANUFACTURERS
- Acceptable Manufacturer: Stromberg Architectural Products Inc; PO Box 8036, I-30 West, 4400 Oneal, Greenville, TX 75404. ASD. Tel: (903) 454-0904. Fax: (903) 454-3642. Email: [email protected]. www.strombergarchitectural.com.
 - Substitutions: Not permitted.
 - Requests for substitutions will be considered in accordance with provisions of Section 01600.
 
2.2 MATERIALS
- 
        Glass Fiber Reinforced Concrete Benches:  High density concrete made of ASTM C 150 Portland cement, crushed stone, silica sand, and polymers reinforced with glass fiber and structural reinforcing as required; asbestos free.
        
- Color: As selected from manufacturer's selection.
 - Color: To match Architect's sample.
 - Surface Texture: Exposed surface as selected from manufacturer's selection.
 - 
            Style:  (Select One) [Manufacturer's Model Number: [bn_001] [bn_002] [bn_003] [bn_004] [bn_005] [bn_006] [As indicated in drawings.]
            
- Bench Dimensions: (Select One) [__ft. __in. long, __ft.__in. wide] [As indicated on drawings.]
 - Bench Height: (Select One) [___ft. ___in.] [As indicated on drawings.]
 
 - Density: 140 pcf (2240 kg/cu m).
 - Shell Thickness: 3/8" to 3/4 inch (9.5 mm), nominal.
 - Surface Burning Characteristics: Flame spread index of 0, smoke developed index of 5; when tested in accordance with ASTM E 84. Fuel contribution of 3.
 - Weather Resistance: No significant loss in strength or change in appearance after 200 hours accelerated weathering conducted in accordance with ASTM G 23.
 - Flexural Strength: 1000 to 1800 psi (6.9 to 12.4 MPa).
 - Modulus of Elasticity: 2 x 10^5 psi (1370 MPa).
 - Compressive Strength: Over 5000 psi (34 MPa).
 - Variation from Dimensions Indicated on Drawings: Plus and minus 1/8 inch (3 mm), maximum.
 - Variation from Plane Along Edge or Surface: Plus and minus 1/16 inch per linear foot (1.5 mm in 300 mm), maximum.
 - Outside Corner Radius: 1/16 inch to 1/8 inch (1.5 to 3 mm).
 - Draft Angle: 3 degrees, minimum, on returns, setbacks, reveals, and grooves.
 - Provide non-corrosive screwed or bolted anchors with reinforced holes through face of units.
 - 
            Provide non-corrosive anchors and reinforced anchoring points as indicated on drawings.
            
- Exposed Anchors: Type 304 Stainless Steel unless otherwise indicated.
 - Concealed Anchors: Hot-dipped Galvanized Steel unless otherwise indicated.
 
 
 
PART 3 EXECUTION
3.1 EXAMINATION
- Do not begin installation until substrates have been properly constructed; verify that substrates are plumb and true.
 - 
        If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding.
        
- Proceed with installation only after unsatisfactory conditions have been corrected.
 
 - Check field dimensions before beginning installation. If dimensions vary too much from design dimensions for proper installation, notify Architect and wait for instructions before beginning installation.
 
3.2 PREPARATION
- Clean surfaces thoroughly prior to installation.
 - Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.
 
3.3 INSTALLATION
- Install in accordance with applicable code and manufacturer's recommendations, plumb and true to line; shim where necessary.
 - Patch exposed anchor points to match color and texture of unit.
 - 
        Clean GFRC units according to manufacturer's written instructions.
        
- Remove dirt, stains, excess sealant or other undesired materials.
 - Protect surrounding materials and surfaces during cleaning.
 
 
3.4 PROTECTION
- Protect installed products until completion of project.
 - Touch-up, repair or replace damaged products before Substantial Completion.
 
END OF SECTION